TitleProduct

Hemoclip for Gastrointestinal Endoscopy

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2022-01-03 01:34

  • Browse the number:

    485

Send an inquiries

Company Profile

Zhejiang Chuangxiang Medical Technology Co., Ltd

By certification [File Integrity]

Contact:chuangxiang888(Mr.)  

Email:

Telephone:

Phone:

Area:Zhejiang

Address:Zhejiang

Website:http://www.mednovahz.com/ http://chuangxiang888.ksfelt.com/

Product Details

Product Model

Model

Order Number

Working Length(mm)

Clip opening(mm)

Claw Angle℃

Rotatable

S

MD-S-HR-195-9-135-Y

1950

9

135

YES

MD-S-HR-230-9-135-Y

2300

9

135

YES

G

MD-G-HR-195-12-135-Y

1950

12

135

YES

MD-G-HR-230-12-135-Y

2300

12

135

YES

C

MD-C-HR-195-13-135-Y

1950

13

135

YES

MD-C-HR-230-13-135-Y

2300

13

135

YES

L

MD-L-HR-195-15-135-Y

1950

15

135

YES

MD-L-HR-230-15-135-Y

2300

15

135

YES

A

MD-A-HR-195-15-135-Y

1950

16

135

YES

MD-A-HR-230-15-135-Y

2300

16

135

YES


Brand

MEDNOVA

OEM available


Certificates

ISO/CE/FDA/CFDA/Russia Registration etc.


Indication 

MEDNOVA hemoclip is indicated for clip placement within the Gastro-intestinal (GI)  tract for the purpose of: 

1. Endoscopic marking, 

2. Hemostasis for: 

Mucosal/Sub-mucosal defect <3 cm; 

Bleeding ulcers; 

Arteries <2mm; 

Polyps <1.5cm in diameter; 

Diverticula in the colon 

3. Anchoring to affix jejuna feeding tubes to the wall of the small bowel; 

4. As a supplementary method, closure of GI tract luminal. 


Features

All-in-one design of gastrointestinal clip;

Short left body parts, make surgery safer;

Clip is large opening designed, capable of grasp a sizeable amount of tissue;

Can be repeated opening and closing, may achieve repositioning;

360-Degree rotatable, convenient clinical operation;

Variety spans of 9mm,12mm,13mm, 15mm and 16mm,which fully meet the different requirements.


MR Conditional

The vitro simulative test on single sterile repositionable hemoclip demonstrate that, according to the ASTM F2503 standard, patients with one clip or multiple dispersive clips or even multiple centralized clips which not touch each other, could get safely scanned under magnetic resonance parameters as MR instructions.


Caution

If there are more than one of these clips in a single location in the body and multiple clips touch each other, the consequences of MRI scanning have not been adequately studied. We suggest performing MRI scan after clips getting off along with the connective tissues. 


http://www.mednovahz.com/